Share
HY-HP-200 laboratory high-purity germanium gamma spectrometer
Are you still hesitating? Get samples first and contact us!
Classification:
Key words:
Monitoring System
- Product Description
-
Low-background lead chamber
2. Top-opening design
2. Lead chamber thickness: 20cm (Optional 25cm ultra-low background lead chamber)
3. Lead chamber structure from outside to inside: Low-carbon steel lining, old lead, tin and soft copper lining
4. Background: 50keV ~ 2MeV integral background <2cps Inner lining: 3mm oxygen-free copper
5. Weight <2.5 tons
High-purity germanium detector
2. Detector model: GCD-50290 Relative efficiency: 50%
2. Detector type: P-type coaxial type
3. Resolution: ≤ 2.9keV@2332keV
4. Peak-to-Compton ratio: ≥ 64:2
5. Peak Shape Parameters FW.2M/FWHM Better than 2.9; F W.02M/FWHM
6. Better than 2.65
7. Liquid nitrogen tank: Standard 30L Dewar flask
The HYGP-2223 type is a small high-sensitivity X-gamma radiation detector, which uses the latest low-power embedded microprocessor as the data processing unit, and the detector is composed of a highly sensitive scintillator and a high-range GM counter. The instrument is more sensitive to short-term pulse radiation and can detect short-term (≥ 20ms)X-pulse radiation. It has a wide range of uses, such as environmental monitoring (nuclear safety), radiation health monitoring (disease control, nuclear medicine), homeland security monitoring (entry and exit, customs), public safety monitoring (public security), nuclear power plants, laboratories and nuclear technology applications.
Instrument features
▶Large area color display with backlight
▶High instrument sensitivity, can measure the environmental background
▶Automatically save the accumulated dose, power can be saved for a long time
Main technical indicators
▶Continuous radiation field measurement range: dose rate: 0.02 μSv/h-200mSv/h
Cumulative dose: 0.00μSv ~ 9999Sv
▶Measurement range of pulsed radiation field: 0.02 μSv/h-200mSv/h
▶Pulse radiation response time: 5ms
▶Energy range: 20KeV-7MeV
▶Sensitivity: 2.7cps 2500cps (2 μSv/h)
HY-HP-200 laboratory high-purity germanium gamma spectrometer
The HYGP-2223 type is a small high-sensitivity X-gamma radiation detector, which uses the latest low-power embedded microprocessor as the data processing unit, and the detector is composed of a highly sensitive scintillator and a high-range GM counter. The instrument is more sensitive to short-term pulse radiation and can detect short-term (≥ 20ms)X-pulse radiation. It has a wide range of uses, such as
Still hesitating? Get the samples first,Contact us!
Classification:
Key words:
Monitoring System
Request Quotation
Note: Please leave your E-mail address and our professionals will contact you as soon as possible!