hotline:020-29026320 |13903018415
-
-
Radiation detection instrumentation
-
HYGP-2223 exposure type X, γ radiation measuring instrument
-
HYGP-2223BX, gamma dose rate meter (with tripod)
-
FI-329M intelligent household nuclear radiation detector
-
HY-2000M digital multi-channel gamma spectrometer
显示更多 -
-
Laboratory Equipment
-
Radioactive distillation apparatus in water
-
2200Q portable turbidity meter
-
SPE Solid Phase Extraction Device
-
Portable spectrophotometer
显示更多 -
-
Portable environmental monitoring equipment
-
VOCs gas analyzer
-
Portable handheld VOC detector
-
Portable all-in-one multi-parameter analyzer
-
Dust detector
显示更多 -
-
Environmental online monitoring system
-
CM-WG8200 grid air quality detection system
-
On-line monitoring system for CM-VOCs-5000 volatile organic compounds
显示更多 -
-
UAV Online Environmental Monitoring
-
OS-2 UAV Electromagnetic Environment Monitoring System
-
Nuclear emergency radioactive source search UAV
-
UAV Monitoring System
显示更多 -
-
On-line Monitoring System of Electromagnetic Radiation
-
On-line Monitoring System of Electromagnetic Radiation
-
Automatic Monitoring System of HYEH460 Electromagnetic Radiation
-
HY-900A launch type radiation environment automatic monitoring station
-
OS-8 S Frequency Selective Electromagnetic Environment Online Monitoring System
显示更多 -
-
Construction requirements for water quality online monitoring station and indoor requirements for monitoring sub-station
2024-10-12
In order to implement the "national key monitoring enterprises pollution source automatic monitoring data validity audit measures" and "national key monitoring enterprises pollution source automatic monitoring equipment supervision and assessment procedures" (Huanfa [9] No. 88) and other relevant provisions, standardize the national key monitoring enterprises pollution source automatic monitoring equipment supervision and assessment of qualified management measures. In order to provide a suitable working environment for the water quality analyzer, according to the requirements of the Technical Specification for Installation of Water Pollution Online Monitoring System (Trial)-HJ/T-7, enterprises are required to set up special water quality online monitoring stations and supporting equipment.
Construction of monitoring sub-station house
The monitoring sub-station house should be built close to the sample source (discharge port or channel) as far as possible to reduce the analysis delay.
The area of monitoring sub-station room should be larger than 20m2. The ground where the instrument is placed shall be paved with floor tiles, which shall be flat and level, corrosion-resistant and vibration-free. The ground of the instrument shall be more than 300mm higher than the ground of the sampling port to ensure that there shall be no protrusion or depression in the middle of the distributed pipeline.
On the wall surface of the monitoring sub-station near the sewer, corresponding holes shall be opened according to the requirements, and the required pipes shall be laid in advance.
At present, the use of many color steel plate room, color steel plate room has the advantages of fast construction speed, low cost, generous appearance, no decoration.
Indoor requirements for monitoring sub-station room
2 Power supply
Single-phase alternating current: power supply voltage: 220V 25% AC, power supply frequency: 50Hz 5%, power supply power: more than 2000w (the power of this equipment does not include water pump is about 350W, the total power of power supply is ≈ the sum of the power of all monitoring equipment + the sum of the power of all external submersible pumps + air conditioning power + at least 20% margin), and should be well grounded. It is equipped with at least 5 three-eye sockets and 2 two-eye sockets, which are fixed at a height of 2.2 meters, or equipped with two multi-function power supply boards, which can be extended to connect water pumps, computers and other electrical equipment.
For areas with unstable voltage and frequent power outages, it is recommended to use a power-matched AC power regulator to protect the instrument.
2 Indoor requirements
Indoor lighting shall be able to shine on the front of the instrument (40W fluorescent lamp);
Dry, ventilated and meet the operating environment temperature of the equipment (air conditioning should be installed to keep the constant temperature at 5-30 ℃), and avoid direct sunlight;
Avoid strong electromagnetic interference;
Avoid strong corrosive gases.
A sink is available for hand washing during maintenance.
recommend News

COOKIES
Our website uses cookies and similar technologies to personalize the advertising shown to you and to help you get the best experience on our website. For more information, see our Privacy & Cookie Policy
COOKIES
Our website uses cookies and similar technologies to personalize the advertising shown to you and to help you get the best experience on our website. For more information, see our Privacy & Cookie Policy
These cookies are necessary for basic functions such as payment. Standard cookies cannot be turned off and do not store any of your information.
These cookies collect information, such as how many people are using our site or which pages are popular, to help us improve the customer experience. Turning these cookies off will mean we can't collect information to improve your experience.
These cookies enable the website to provide enhanced functionality and personalization. They may be set by us or by third-party providers whose services we have added to our pages. If you do not allow these cookies, some or all of these services may not function properly.
These cookies help us understand what you are interested in so that we can show you relevant advertising on other websites. Turning these cookies off will mean we are unable to show you any personalized advertising.
online message
Telephone:13903018415(Manager Wang)
Business: 020-29026320
E-mail:wangxueli@haiyoukj.com
Address: Room 703, Tian 'an Innovation Building, Panyu Energy Saving Science Park, 555 Panyu Avenue North, Donghuan Street, Panyu District, Guangzhou

Sweep code attention